  for more information, please visit the product page | for information on related products, view dc power jacks ????????? ?????????????????? cui .com 05/08/2015 1 of 6 series : etsa 150w u description: ac-dc power supply model output voltage output current output power ripple and noise 1 effciency level (vdc) max (a) max (w) max (mvp-p) etsa1201167u 12 11.67 140 240 vi etsa160938u 16 9.38 150 320 vi etsa190790u 19 7.90 150 380 vi ETSA240625U 24 6.25 150 480 vi etsa360417u 36 4.17 150 480 vi etsa480313u 48 3.13 150 480 vi notes: 1. ripple and noise measured with 20 mhz bandwidth oscilloscope, each output terminated with 10 f/50 v electrolytic and 0.1 f cer amic capacitors. part number key features ? 150 w power ? universal input (90~264 vac) ? single regulated outputs ? over voltage, over current, and short circuit protections ? ul/cul safety approvals ? level vi efficiency ? power factor correction ? custom designs available base number example of 16 vdc, 9.38 a reserved for custom confgurations etsa160938u x - p51 - wp - cxx dc plug type: 4 pin power din factory designation input cable: blank = no cable c = north america input cable 2 = europe input cable 3 = united kingdom input cable 4 = australia input cable 5 = china input cable 6 = south korea input cable 7 = brazil input cable 8 = south africa input cable 9 = japan input cable date page
for more information, please visit the product page | for information on related products, view dc power jacks ?????????????????? cui .com date 05/08/2015 page 2 of 6 cui inc series : etsa 150w u description: ac-dc power supply input parameter conditions/description min typ max units voltage 90 264 vac frequency 47 63 hz current at 90 vac, 50 hz 2.5 a inrush current at 230 vac, cold start 150 a power factor correction at full load 0.9 no load power consumption 0.15 w output parameter conditions/description min typ max units regulation 12, 16, 19 vdc output models 24, 36, 48 vdc output models 5 3 % % hold-up time at 115/230 vac, full load 16 ms temperature coeffcient 0.05 %/c protections parameter conditions/description min typ max units over voltage protection output latch off 110 130 % over current protection output shut down, auto recovery 110 160 % short circuit protection output shut down, auto recovery safety & compliance parameter conditions/description min typ max units isolation voltage input to output for 4 seconds input to frame ground for 4 seconds 4,242 2,121 vdc vdc isolation resistance input to output at 500 vdc input to frame ground at 500 vdc 20 20 m ? m ? safety approvals ul/cul, gs emi/emc fcc part 15 class b, en55022/en55024 class b, ce mtbf at full load, 25c 140,000 hours rohs 2011/65/eu environmental parameter conditions/description min typ max units operating temperature derate linearly 2.5% per c from 41~60c 0 60 c storage temperature -10 85 c operating humidity non-condensing 20 90 % storage humidity non-condensing 20 90 %
for more information, please visit the product page | for information on related products, view dc power jacks ?????????????????? cui .com date 05/08/2015 page 3 of 6 cui inc series : etsa 150w u description: ac-dc power supply mechanical drawing units: mm tolerance: 0.5 mm mechanical parameter conditions/description min typ max units dimensions 170 x 85 x 44 mm inlet plug iec320 / c14
for more information, please visit the product page | for information on related products, view dc power jacks ?????????????????? cui .com date 05/08/2015 page 4 of 6 cui inc series : etsa 150w u description: ac-dc power supply dc cord model no. cable etsa1201167u 14 awg, black, ul1571, 80c, 30 v, 14 awgx1c + aluminum shield (14 awg) etsa160938u 14 awg, black, ul1571, 80c, 30 v, 14 awgx1c + aluminum shield (14 awg) etsa190790u 14 awg, black, ul1571, 80c, 30 v, 14 awgx1c + aluminum shield (14 awg) ETSA240625U 14 awg, black, ul1571, 80c, 30 v, 14 awgx1c + aluminum shield (14 awg) etsa360417u 16 awg, black, ul1185 80/90c, 300 v, 16 awgx1c + aluminum shield (16 awg) etsa480313u 16 awg, black, ul1185 80/90c, 300 v, 16 awgx1c + aluminum shield (16 awg) see t able 1 sectional drawin g 4p power din front view table 1 units: mm
for more information, please visit the product page | for information on related products, view dc power jacks ?????????????????? cui .com date 05/08/2015 page 5 of 6 cui inc series : etsa 150w u description: ac-dc power supply ac input cord length north america 1,830 mm 50 europe 1,830 mm 30 united kingdom 1,800 mm 50 australia 1,830 mm 30 china 1,830 mm 50 south korea 1,800 mm 30 brazil 1,830 mm 30 south africa 1,830 mm 30 japan 1,830 mm 30 ac cord units: mm north america europe australia united kingdom china cord length south korea south africa brazil japan table 2
for more information, please visit the product page | for information on related products, view dc power jacks ????????? date 05/08/2015 page 6 of 6 cui inc series : etsa 150w u description: ac-dc power supply this device complies with part 15 of the fcc rules. operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. cui offers a one (1) year limited warranty. complete warranty information is listed on our website. cui reserves the right to make changes to the product at any time without notice. information provided by cui is believed to be accurate and reliable. however, no responsibility is assumed by cui for its use, nor for any infringements of patents or other rights of third parties which may result from its use. cui products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. a critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safet y or effectiveness. headquarters 20050 sw 112th ave. tualatin, or 97062 800.275.4899 fax 503.612.2383 cui .com techsupport@cui.com rev. description date 1.0 initial release 11/22/2013 1.01 added ac cord options 10/09/2014 1.02 updated to level vi effciency 05/08/2015 the revision history provided is for informational purposes only and is believed to be accurate. revision history


▲Up To Search▲   

 
Price & Availability of ETSA240625U

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X